Relationships
Classes
brick: Fan Coil UnitCLASSv1.0.3
Equivalent Classes
Parent Classes
brick: AHU Building Exhaust Fans Stage CommandCLASSv1.0.3
Definitions
Exhaust fans are typically arranged so that they can be fired in stages as per requirement. This command controls which stage is switched on
brick: Building Exhaust Fans Stage CommandCLASSv1.0.3
Definitions
Exhaust fans are typically arranged so that they can be fired in stages as per requirement. This command controls which stage is switched on
Parent Classes
brick: AHU CO2 Differential SensorCLASSv1.0.3
Definitions
Sensor that measures the difference in CO2 level between any two points in the system.
brick: CO2 Differential SensorCLASSv1.0.3
Definitions
Sensor that measures the difference in CO2 level between any two points in the system.
Parent Classes
brick: AHU Change Filter AlarmCLASSv1.0.3
Definitions
Alarm to change dirty filter
Parent Classes
brick: Change Filter AlarmCLASSv1.0.3
Definitions
Alarm to change dirty filter
Parent Classes
brick: AHU Cooling Valve CommandCLASSv1.0.3
Definitions
Can also be part of CRAC
brick: AHU Dual Band Mode SetpointCLASSv1.0.3
Definitions
virtual point used for controls
brick: Dual Band Mode SetpointCLASSv1.0.3
Definitions
virtual point used for controls
Parent Classes
brick: AHU Economizer Damper Min Position SetpointCLASSv1.0.3
Definitions
Part of economizer to ensure minimum air flow
brick: Economizer Damper Min Position SetpointCLASSv1.0.3
Definitions
Part of economizer to ensure minimum air flow
brick: AHU Economizer Differential Air Temperature SetpointCLASSv1.0.3
Definitions
Difference between return air flow and outside air flow
brick: Economizer Differential Air Temperature SetpointCLASSv1.0.3
Definitions
Difference between return air flow and outside air flow
brick: AHU Economizer Mode StatusCLASSv1.0.3
Definitions
virtual point used for controls
brick: AHU Economizer StatusCLASSv1.0.3
Definitions
virtual point used for controls
brick: Economizer Mode StatusCLASSv1.0.3
Definitions
virtual point used for controls
brick: AHU Overridden Off StatusCLASSv1.0.3
Definitions
Indicates if the AHU has been manually overridden to be Off
brick: AHU Overridden On StatusCLASSv1.0.3
Definitions
Indicates if the AHU has been manually overridden to be On
brick: AHU Exhaust Fan System Enable CommandCLASSv1.0.3
Definitions
Enable switch for a collection of exhaust fans
brick: AHU Exhaust Fan Enable CommandCLASSv1.0.3
Definitions
Enable switch for one particular exhaust fan
brick: Exhaust Fan System Enable CommandCLASSv1.0.3
Definitions
Enable switch for a collection of exhaust fans
brick: AHU Fan Run Request StatusCLASSv1.0.3
Definitions
Request from AHU for the fan to run
brick: Fan Run Request StatusCLASSv1.0.3
Definitions
Request from AHU for the fan to run
brick: AHU Low Outside Air Temperature Enable SetpointCLASSv1.0.3
Definitions
Temperature at which outside air is Low
brick: Low Outside Air Temperature Enable SetpointCLASSv1.0.3
Definitions
Temperature at which outside air is Low
brick: AHU Max VFD Speed SetpointCLASSv1.0.3
Definitions
Max VFD Speed To Increase Static Pressure Setpoint
brick: Max VFD Speed SetpointCLASSv1.0.3
Definitions
Max VFD Speed To Increase Static Pressure Setpoint
Parent Classes
brick: AHU Min VFD Speed SetpointCLASSv1.0.3
Definitions
Min VFD Speed To Increase Static Pressure Setpoint
Parent Classes